MII Mgmt Command register.
READ | This bit causes the MII Management hardware to perform a single Read cycle. The Read data is returned in Register MRDD (MII Mgmt Read Data). |
SCAN | This bit causes the MII Management hardware to perform Read cycles continuously. This is useful for monitoring Link Fail for example. |
RESERVED | Unused |